Availability: | |
---|---|
Quantity: | |
A415A
STIER
The A415A Washing Module is a core component designed for integration into STIER's Rank A415 framework system, used within advanced laboratory glassware washers like the S8000D series. It enables the automated, thorough cleaning and drying of a wide variety of essential lab glassware, critical for maintaining contamination-free workflows in scientific environments.
Model | A615D 6×15 Module (80 mm) | A306X3 3×6 Module (150 mm) |
Dimensions (H×W×D) | 113 × 199 × 472 mm | 183 × 184 × 472 mm |
Ideal For | Celine bottles, weighing boats, etc. | Volumetric flasks, Erlenmeyer flasks, round bottom flasks, Schott flasks, measuring cylinders |
Nozzle Configuration | 88 × S400800B injector nozzles (H: 80 mm) | 9 × S601506A injector nozzles (H: 150 mm) |
Figure | ![]() | ![]() |
For optimal performance and longevity of the washing module and the overall glassware washer system, adhere to these routine checks:
1. Operational Noise & Synchronization:
A. Listen for any unusual sounds during operation.
B. Verify all mechanical components are moving in a coordinated and synchronized manner.
2. Hardware Integrity:
A. Regularly inspect all fasteners (bolts, screws) throughout the instrument for looseness.
B. Tighten any loose fasteners immediately upon discovery.
3. Utility Supply Conditions:
A. Confirm water pressure and air pressure are within the required operational ranges.
B. Ensure cleaning/drying liquid temperatures meet the specified requirements for the cycle.
4. Nozzle & Component Health:
A. Check spray nozzles for blockages and clean as necessary.
B. Monitor the temperature of gearboxes and bearings; ensure they remain within normal operating limits.
5. Basket & Filtration Inspection:
A. Examine bottle basket openings for damage.
B. Check the inclined filter screen for blockages.
C. Critical Action: If the liquid level difference across the inclined filter screen exceeds 100mm, the filter must be cleaned promptly to maintain proper flow and cleaning efficacy.
Feature | Description |
Modular Flexibility | Compatible with Rank A415 framework system for automated glassware washers (e.g., S8000D series). |
Specialized Configurations | Dedicated modules (A615D, A306X3) optimized for specific labware types and sizes. |
High-Impact Cleaning | Precision injector nozzles ensure thorough spray coverage (88 nozzles for small items; 18 nozzles for complex glassware). |
Durability | Stainless steel construction built for integration into industrial-grade lab washers. |
Compliance-Ready | Supports effective cleaning protocols for GLP/GMP and lab hygiene standards. |
Ease of Maintenance | Design allows routine checks of nozzles, filters, and fasteners (per maintenance guidelines). |
Why Choose STIER?
STIER specializes in laboratory cleaning solutions with a comprehensive understanding of industry regulations. They offer expertise in customizing cleaning solutions to meet specific customer requirements.
Company: STIER (Guangzhou) Instrument Co., Ltd.
Address: 207, Building 4, Qixi Creative Industrial Park, No. 24 Xinyi Road, Liwan District, Guangzhou, China
Telephone: +86-20-81579281
E-mail:info@stier-instrument.com
Website: www.stier-instrument.com
The A415A Washing Module is a core component designed for integration into STIER's Rank A415 framework system, used within advanced laboratory glassware washers like the S8000D series. It enables the automated, thorough cleaning and drying of a wide variety of essential lab glassware, critical for maintaining contamination-free workflows in scientific environments.
Model | A615D 6×15 Module (80 mm) | A306X3 3×6 Module (150 mm) |
Dimensions (H×W×D) | 113 × 199 × 472 mm | 183 × 184 × 472 mm |
Ideal For | Celine bottles, weighing boats, etc. | Volumetric flasks, Erlenmeyer flasks, round bottom flasks, Schott flasks, measuring cylinders |
Nozzle Configuration | 88 × S400800B injector nozzles (H: 80 mm) | 9 × S601506A injector nozzles (H: 150 mm) |
Figure | ![]() | ![]() |
For optimal performance and longevity of the washing module and the overall glassware washer system, adhere to these routine checks:
1. Operational Noise & Synchronization:
A. Listen for any unusual sounds during operation.
B. Verify all mechanical components are moving in a coordinated and synchronized manner.
2. Hardware Integrity:
A. Regularly inspect all fasteners (bolts, screws) throughout the instrument for looseness.
B. Tighten any loose fasteners immediately upon discovery.
3. Utility Supply Conditions:
A. Confirm water pressure and air pressure are within the required operational ranges.
B. Ensure cleaning/drying liquid temperatures meet the specified requirements for the cycle.
4. Nozzle & Component Health:
A. Check spray nozzles for blockages and clean as necessary.
B. Monitor the temperature of gearboxes and bearings; ensure they remain within normal operating limits.
5. Basket & Filtration Inspection:
A. Examine bottle basket openings for damage.
B. Check the inclined filter screen for blockages.
C. Critical Action: If the liquid level difference across the inclined filter screen exceeds 100mm, the filter must be cleaned promptly to maintain proper flow and cleaning efficacy.
Feature | Description |
Modular Flexibility | Compatible with Rank A415 framework system for automated glassware washers (e.g., S8000D series). |
Specialized Configurations | Dedicated modules (A615D, A306X3) optimized for specific labware types and sizes. |
High-Impact Cleaning | Precision injector nozzles ensure thorough spray coverage (88 nozzles for small items; 18 nozzles for complex glassware). |
Durability | Stainless steel construction built for integration into industrial-grade lab washers. |
Compliance-Ready | Supports effective cleaning protocols for GLP/GMP and lab hygiene standards. |
Ease of Maintenance | Design allows routine checks of nozzles, filters, and fasteners (per maintenance guidelines). |
Why Choose STIER?
STIER specializes in laboratory cleaning solutions with a comprehensive understanding of industry regulations. They offer expertise in customizing cleaning solutions to meet specific customer requirements.
Company: STIER (Guangzhou) Instrument Co., Ltd.
Address: 207, Building 4, Qixi Creative Industrial Park, No. 24 Xinyi Road, Liwan District, Guangzhou, China
Telephone: +86-20-81579281